Product Overview: All-in-one System single Phase High Voltage(5/6kW)

Specifications and Parameters:

Type Designation All-in-one sys 5kW SH All-in-one sys 6kW SH
PV (input)
Max.recommended PV array power 12000 Wp 13000 Wp
Max. Pv input voltage 600 V
Min. operating PV voltage 40 V
Start-up input voltage 50 V
Rated PV input voltage 360 V
MPPT Voltage Range 40-560 V
No. of MPPT/Strings per MPPT 2(1/1)
Max. pv input current 32 A (16 A/ 16 A)
Max, current for each input connector 40A(20 A/20 A)
Max.DC short-circuit current 20 A
Battery
Battery type Lithium-ion battery
Max.charge/discharge current 30 A/30 A
Nominal voltage range 192~512 V(64V per module)
Nominal capacity range 9.6 kWh~25.6 kwh (3.2 kwh / 50 Ah per module)
Number of connectable modules 3~8 modules
Backup Output (on-Grid Mode)
Rated output power 6000 W
Rated output current 27 A
Backup Output (off-Grid Mode)
Rated output power 5000 W/5000 VA 6000 W/6000 VA
Peak output power 8400 VA, 10S
Backup switching time <10 ms
Rated voltage 220V/230 V/240 V(+2 %)
Frequency range 50 Hz / 60 Hz (±0.5 %)
Total harmonic distortion (THDv, rated power, linear load) ≤2%
Grid (input/output)
Max. AC input power from grid 12000VA 13000VA
Rated AC output power 5000 W 6000W
Max. AC output power 5000 VA 6000VA
Rated AC output current (at 230V) 21.8 A 26.1 A
Max. AC output current 22.8 A 27.3 A
Rated AC voltage 220V/230V/240V
AC voltage range 154-276 V
Rated AC frequency 50 Hz/60 Hz
Grid frequency range 45-55 Hz/55-65 Hz
Harmonic (THD) <3 %
Power factor at rated power >0.99
Adjustable power factor adjustable 0.8.leading to 0.8 lagging
Effciency
Max.effciency/European effciency 97.7%/97.3 % 97.7%/97.3 %
Protection & Function
Surge Protection DC type ll/Ac type ll
Gird monitoring Yes
DC reverse polarity protection Yes
Battery input reverse polarity protection Yes
AC short-circuit protection Yes
Leakage current protection Yes
DC swith (PV) Yes
DC fuse (Battery) Yes
General Data
Topology (PV/Battery) Transformerless /Transformerless
Degree of protection IP 65
Dimensions (W*H*D) 640*1012*360 mm (With 3 Battery modules)
Weight <132 kg (With 3 Battery modules)
Mounting method Floor-standing
Operating ambient temperature range -25 °C to 60 °C
Storage temperature -20°C to 45 °C(≤1 Months)/-20°C to 25 °(≤6 Months)
Allowable relative humidity range 5-95 %
Cooling method Natural convection
Max. operating altitude 2000 m
Display LED indicator
Communication RS485 /CAN / WLAN
DI/DO 1*DI/1*DO/DRM
DC connection type MC4
Battery connection type MC4
AC connection type Screws & Fasteners
STANDARD
Safety EN/IEC62109-1/2
EMC ENIEC61000-6-1/3
Certification G99/EN50549/RD1699/UNE217001