Tensiwn AC enwiedig:3/n/pe 220v/380v 230v/400v 240v/415v
ystod foltedd ac:270v~480v
amseroedd gridd enwi:50hz/60hz
ystod amlder y grid:45~55hz/55~65hz
Harmonig (dd) ar faich enwi: <3%
Ffector pŵer ar bŵer enwi:>0.99
ffactwr pŵer addasu:adj.0.8.mwy o gyffro/sy'n arwain at 0.8 is-gyffro/hysgod
math grid:tryd-fases
manylion a pharamedrau:
dynodiad math | sih-5kw-th |
sih-6kw-th | sih-8kw-th | sih-10kw-th |
mewnbwn (pv) | ||||
argymell uchafswm, pŵer mewnbwn pv | 7500wp | 9000wp | 12000wp | 15000wp |
foltedd mewnbwn max.pv | 1000v | |||
foltedd mewnbwn cychwyn | 180v | 250v | 250v | 250v |
foltedd mewnbwn pv graddedig | 600v | |||
ystod foltedd mppt | 150-950v | 200-950v | 200-950v | 200-950v |
mewnbynnau mppt no.ofindependent | 2 | |||
rhagosodiad dim. o dannau pv fesul mppt | 1\1 | 1\1 | 1\1 | 1\2 |
uchafswm, cerrynt mewnbwn | 32a(16a/16a) | 32a(16a/16a) | 32a(16a/16a) | 48a(16a/32a) |
max.input cylched byr cyfredol | 40a(20a/20a) | 40a(20a/20a) | 40a(20a/20a) | 60a(20a/40a) |
mewnbwn/allbwn(ac) | ||||
pŵer mewnbwn max.ac o'r grid | 12500va | 15000va | 18600va | 20600va |
pŵer allbwn graddedig cerrynt eiledol | 5000w | 6000w | 8000w | 10000w |
max. pŵer allbwn cerrynt eiledol | 5500va | 6600va | 8800va | 11000va |
cerrynt allbwn cerrynt eiledol â sgôr | 7.6a | 9.1a | 12.1a | 15.2a |
max. cerrynt allbwn cerrynt eiledol | 8.4a | 10a | 13.3a | 16.7a |
foltedd cerrynt eiledol | 3/n/pe 220v/380v 230v/400v 240v/415v | |||
amrediad foltedd cerrynt eiledol | 270v ~ 480v | |||
amlder grid graddedig | 50hz/60hz | |||
ystod amlder grid | 45 ~ 55hz / 55 ~ 65hz | |||
harmonig(thd)yn ôl y baich graddedig | < 3% | |||
ffactor pŵer ar bŵer â sgôr | >0.99 | |||
ffactor pŵer addasadwy | adj.0.8.overexcited/arwain at 0.8 underexcited/lag | |||
math grid | tri cham | |||
data batri | ||||
math batri | batri li-ion | |||
foltedd batri | 150-600v | |||
max. codi tâl cyfredol | 30a | |||
max. cerrynt rhyddhau | 30a | |||
pŵer max.charge | 7500w | 9000w | 10600w | 10600w |
max. pŵer rhyddhau | 6000w | 7200w | 10600w | 10600w |
data cyffredinol | ||||
dimensiynau (w*h*d) | 450*550*185mm | |||
pwysau | 31kg | |||
dull mowntio | braced gosod wal | |||
topoleg (solar/batri) | di-drawsnewidydd/di-drawsnewidydd | |||
gradd o amddiffyniad | ip65 | |||
gweithredu ystod tymheredd amgylchynol | -25 ° c ~ 60 ° c, dim gradd islaw 45 ° c | |||
ystod lleithder cymharol a ganiateir | 0 ~ 100% | |||
dull o oeri | darfudiad naturiol | |||
max. uchder gweithredu | 4000m | |||
arddangos | arwain | |||
cyfathrebu | rs485/can/wlan | |||
di/gwneud | dix1/dox1/drm | |||
math o gysylltiad dc | mc4 | |||
math o gysylltiad batri | mc4 | |||
math cysylltiad c | plwg a chwarae cysylltydd | |||
data wrth gefn (ar-grid) | ||||
pŵer allbwn graddedig ar gyfer llwyth wrth gefn | 6000 gw | |||
cerrynt allbwn graddedig ar gyfer llwyth wrth gefn | 27a | |||
data wrth gefn (model oddi ar y grid) | ||||
fwltedd enwi | 3/n/pe 220 vac/230 vac/240 vac (±2%) | |||
ystod amlder | 50hz/60hz(+0.5%) | |||
thdv cyfanswm allbwn ar gyfer llwyth leinin | ≤2% | |||
newid amser i'r modd brys | ≤10 ms | |||
pŵer allbwn graddedig | 5000w/5000va | 6000w/6000va | 8000w/8000va | 10000w/10000va |
pŵer allbwn brig | 6000va 5 munud/10000 va,10s | 7200va 5 munud/10000 va,10s | 9600 va, 5 munud | 12000 va, 5 munud |
nodweddion y cynnyrch:
perfformiad rhagorol.
Foltedd cychwyn isel ychwanegol o 180v
effeithlonrwydd mwyaf 98.4%
max.10.6kw tâl/pŵer rhyddhau
allbwn anghymesur tri cham
llai na 100% o lwythi anghytbwys
cymwysiadau hyblyg.
cefnogi cysylltiad aml-gyfochrog
offer gyda dl\do porthladd
mewnbwn max.16a dc
llwyth gwych oddi ar y grid.
copi wrth gefn cartref cyfan
cefnogi llwyth hanner ton a llwyth sioc
<10ms newid oddi ar y grid
dylunio cyfeillgar.
dyluniad marw-castio, dyluniad heb gefnogwr, sŵn isel
cefnogi afci
datrys problemau o bell ac uwchraddio rhaglenni
dulliau gweithredu lluosog deallus ar gael.
hunan-gynhyrchu, sero porthwr pŵer, vpp, di-fatri, di-fatri a di-grid