Specifications and Parameters:
Type Designation | SiH-3.6kW-SL | SiH-5kW-SL | SiH-6kW-SL |
Input (PV) | |||
Recommend max, pv input power | 8700Wp | 10000Wp | 11000Wp |
Max.Pv input voltage | 600V | ||
Min. operating PV voltage | 40V | ||
Start-up input voltage | 50V | ||
Rated PVinput voltage | 360V | ||
No.of independent MPPT inputs | 2 | ||
Default No.of pv strings per MPPT | 1 | ||
Max. PV input current | 16A | ||
Max,DC short-circuit current | 20A | ||
Input/output(Ac) | |||
Max.AC input power from grid | 8700VA | 10000VA | 11000 VA |
Rated Ac output power | 3680W | 5000W | 6000W |
Max. AC output power | 3680VA | 5000VA | 6000VA |
Max. AC output current | 16.7A | 22.8A | 27.3A |
Rated AC voltage | 220V/230V/240V | ||
AC voltage range | 154V~276V | ||
Rated grid frequency | 50HZ/60HZ | ||
Grid freguency range | 45~55Hz/55~65Hz | ||
Harmonic(THD) | <3% | ||
Power factor at rated power | >0.99 | ||
Adjustable power factor | adj.0.8.overexcited/leading to 0.8 underexcited/lagging | ||
Grid Type | Single phase | ||
Battery Data | |||
Battery Type | Li-ion battery | ||
Battery voltage | 40-59V | ||
Max. charge current | 100A | ||
Max. discharge current | 100A | ||
Max.charge power | 5000W | ||
Max. discharge power | 5000W | ||
General Data | |||
Dimensions (W*H*D) | 600*365*194mm | ||
Weight | ≤23.5kg | ||
Mounting method | Wall-mounting bracket | ||
Topology (Solar/Battery) | Transformerless | ||
Degree of protection | IP65 | ||
Operating ambient temperature range | -25°C~60°C | ||
Allowable relative humidity range | 0~100% | ||
Cooling method | Natural convection | ||
Max. operating altitude | 4000m | ||
Display | LED indicator | ||
Communication | RS485/CAN/WLAN | ||
DI/DO | DIx1/DOx1/DRM | ||
DC connection type | MC4 | ||
Battery connection type | MC4 | ||
AC connection type | Screws & Fasteners | ||
Backup Data (on-grid) | |||
Rated output power for backup load | 6000 W | ||
Rated output current for backup load | 27A | ||
Backup Data (off-grid model) | |||
Rated voltage | 220V/230V/240V(+2%) | ||
Frequency range | 50Hz/60Hz(+0.5%) | ||
Total output THDV for liner load | ≤2% | ||
Switch time to emergency mode | ≤10 ms | ||
Rated output power | 3000 W/3000 VA | 5000W/5000VA | 5000W/6000VA |
Peak output power | 8400 VA,10S |
Product Features:
OUTSTANDING PERFORMANCE.
40~59V wide battery voltage range
MaX.5kW charging and discharging
240% Dc input oversizing
50V extra low start-up voltager
FLEXIBLE APPLICATIONS.
Support multi-parallel connection
Equipped with Dl\Do port
MaX.16A DC input
SUPERB OFF-GRID LOAD.
Whole-home backup
Support half-wave load and shock load
<10mS off-grid switching
FRIENDLY DESIGN.
Die-casting design,fanless design, low noise
Support AFCI
Remote troubleshooting and program upgrading
INTELLIGENT MULTIPLE OPERATING MODES AVAILABLE.
Self-generated, zero power feeder, Vpp, battery-free, battery-free & gridless