Specifications and Parameters:
Type Designation | SiH-10KWTH-PRO | SiH-12kW-TH | SiH-15kW-TH | SiH-20kW-TH | SiH-25kW-TH | SiH-30kW-TH |
PV(input) | ||||||
Recommend max, pv input power | 20000Wp | 24000Wp | 30000Wp | 40000Wp | 50000Wp | 60000Wp |
Max.Pv input voltage | 1000V | |||||
Nominal PV input voltage | 650V | |||||
MPP voltage range | 150V-950V | |||||
No. of MPPT /Strings per MPPT | 3 (1/1/1) | 3(1/1/1) | 3 (2/1/1) | 3 (2/2/1) | 3(2/2/2) | |
Max.PV current(PV1/PV2 /PV3) | 48A(16A/16A/16 A) | 64A(32A/16A/16 A) | 80A(32A/32A/16A) | 96A(32A/32A/32A) | ||
Max.short-circuit current(PV1 /PV2 /PV3) | 60A(20A/20A/20A) | 80A(40A/20A/20A) | 100A(40A/40A/20A) | 120A(40A/40A/40A) | ||
Battery (input/output) | ||||||
Battery type | Li-ion battery | |||||
Battery voltage range | 100V-800V | |||||
Max.charge /discharge current | 50A/50A* | |||||
Max.charge /discharge power | 15000W/10000W | 15000W/12000W | 30000W/15000W | 30000W/20000W | 30000W/25000W | 30000W/30000W |
Grid (input/output) | ||||||
Max. AC power from grid | 43000W/43000VA | |||||
Nominal Ac output power | 10000VA | 12000VA | 15000VA | 20000VA | 25000VA | 30000VA |
Max.AC output power | 10000VA | 12000VA | 15000VA | 20000VA | 25000VA | 30000VA |
Max. AC output current | 15.2A | 18.2A | 22.8A | 30.4A | 37.9A | 45.5A |
Rated AC voltage | 3/N/PE,220/380V;230/400V;240/415 V | |||||
AC voltage range | 270V-480V | |||||
Rated grid frequency | 50Hz/60Hz | |||||
Grid frequency range | 45Hz-55Hz/55Hz-65Hz | |||||
THDi (Rated power) | <3% (of rated power) | |||||
Power factor at Rated power / Adjustable power factor |
>0.99 /0.8 leading to 0.8 lagging | |||||
Backup (output) | ||||||
Rated voltage | 3/N/PE.220V;230V;240 V | |||||
Frequency range | 50Hz/60Hz | |||||
THDv (Rated power, Linear load) | 2% | |||||
Back-up switching time | <10ms | |||||
Rated output power during off grid mode | 10000VA | 12000VA | 15000VA | 20000VA | 25000VA | 30000VA |
Peak output power during off grid mode** | 15000W/15000VA 10s |
16800W/168000VA 10s |
25500W/25500VA 10s |
32000W/32000VA 10s |
36500W/36500VA 10s |
45000W/45000VA 10s |
Max. output power for backup load during on grid mode |
43000W/43000VA | |||||
Max.output current for backup load during on grid mode |
3*63A(25°C) | |||||
Efficiency | ||||||
Max.efficiency / European efficiency | 98.0%/97.5 % | 98.1 %/97.6 % | 98.2%/97.8% | |||
General Data | ||||||
Dimensions (W*H*D) | 615 mm*460 mm*245 mm | |||||
Weight | 34kg | 35kg | 36kg | |||
Mounting method | Wall-mounting bracket | |||||
Topology (Solar/Battery) | Transformerless/Transformerless | |||||
Degree of protection | IP65 | |||||
Operating ambient temperature range | -25°C~60°C,No derating below 45 °C | |||||
Allowable relative humidity range (Non-condensing) |
0~100% | |||||
Cooling method | Natural convection | Fan cooling | ||||
Max. operating altitude | 2000m | |||||
Display | LED | |||||
Communication | 2xRS485,WLAN,2 xCAN | |||||
DI/DO | 4xDI,1xDO,DRMO | |||||
DC connection type | MC4 (PV, Max. 6mm²) Plug and play connector (battery, Max.10mm²) | |||||
AC connection type | OT Terminals(grid /backup,Max.20mm²) |
Product Features:
OUTSTANDING PERFORMANCE.
MaX.50A battery charging and discharging design
200% Dc input overmatching
Three-phase asymmetrical output
under 100% unbalanced loads
FLEXIBLE APPLICATIONS.
Support multi-parallel connection
Support single-phase power output mode
100~800V wide battery voltage range
SUPERB OFF-GRID LOAD.
Whole-home backup
Support half-wave load and shock load
<10ms off-grid switching
FRIENDLY DESIGN.
≤ З6KG, lighter installation
Die-casting design, fanless design, low noise
Support AFCI
Remote troubleshooting and program upgrading